Supported Control Devices

NETLABPE control devices provide internal connectivity, console access, and managed power. Control devices are dynamically managed by NETLABPE and are not accessible or configurable by end users.

Control Switches

NETLABPE uses a control switch to provide connectivity between the NETLABPE server,access servers, remote PCs, and switched outlet devices. Control switches are not accessed by lab users.

The following table lists the Cisco switch models supported by NETLABPE for use as a control switch.


Cisco Switch Model Required Image
Catalyst 1912 Enterprise Edition1 9.00.04 Enterprise Edition (or later)
Catalyst 1924 Enterprise Edition1 9.00.04 Enterprise Edition (or later)
Catalyst 2950-12 12.1(22)EA2
Catalyst 2950-24 12.1(22)EA2
Catalyst 2950-48 12.1(22)EA2
Catalyst 2960-24 12.2.25
Catalyst 2960-48 12.2.25
Catalyst 3550-12 12.1(22)EA2
Catalyst 3550-24 12.1(22)EA2
Catalyst 3550-48 12.1(22)EA2
1 End-of-life. Functionality may be limited. Not recommended.

Access servers

Access servers provide console connections to lab equipment. Using this approach, users can access lab gear even when no configurations have been loaded in the lab devices. NETLABPE proxies all connections through the access server. This special proxy allows simultaneous sharing of console ports and allows all users to access the lab environment using a single IP address and single Telnet port.

The following table lists the Cisco devices supported by NETLABPE for use as an access server.

Cisco Model Ports Provided Required Image
NM-32A Module in Cisco Router 32 12.0(5)T or later
NM-16A Module in Cisco Router 16 12.0(5)T or later
2511-RJ 16 12.0(5)T or later
2511 (octal cables) 16 12.0(5)T or later
2509-RJ 8 12.0(5)T or later
2509 (octal cables) 8 12.0(5)T or later

Switched Outlet Devices

Switched outlets provide managed electrical power, allowing NETLABPE and users to turn lab equipment on and off. The power of each managed device in a NETLABPE equipment pod is connected to an American Power Conversion (APC) Switched Rack PDU. This provides three functions:

Each APC Switched Rack PDU provides eight (8) managed outlets. The following table lists the Switched Outlet devices supported by NETLABPE.

Switched Outlet Device Outlets Voltage Outlet Type
APC 7900 Switched Rack PDU 8 120V NEMA 5-15R
APC 7920 Switched Rack PDU 8 208V IEC 320 C13
APC 9211 Master Switch
(end of sales)
8 120V NEMA 5-15R
APC 9212 Master Switch
(end of sales)
8 208V IEC 320 C13

  • The AP7920 and AP9212 are for countries with 200-240 VAC power. Eight (8) IEC-320 C13 outlets are provided. This will require (8) C13 to C14 power cords such as the AP9870 (sold separately). One (1) IEC-320 C14 inlet is provided on the input side. The C14 connector is the same used on a Cisco router or switch.

  •