NETLABPE requires all Catalyst 1912 and 1924 switches to be running Enterprise Edition 9.00.04 or later (these versions support command-line interface and Virtual LAN). If it is not, NETLABPE will not function correctly - you must upgrade the switch. You can use your NETLABPE server to accomplish this upgrade if needed.
Please perform the following tasks to upgrade your switch(es).

Note: Your NETLABPE server may look different than the one
shown here. Please refer to the printed label on your NETLABPE server to
help locate the E0 (eth0) port and the E1 (eth1) port.
User Interface Menu
[M] Menus
[I] IP Configuration
[P] Console Password
Enter Selection: M
|
Catalyst 1900 - Main Menu
[C] Console Settings
[S] System
[N] Network Management
[P] Port Configuration
[A] Port Addressing
[D] Port Statistics Detail
[M] Monitoring
[B] Bridge Group
[R] Multicast Registration
[F] Firmware
[I] RS-232 Interface
[U] Usage Summaries
[H] Help
[X] Exit Management Console
Enter Selection: S
|
Catalyst 1900 - System Configuration
System Revision: 4 Address Capacity: 1024
System UpTime: 0day(s) 01hour(s) 10minute(s) 52second(s)
----------------------- Settings ---------------------------------------
[N] Name of system
[C] Contact name
[L] Location
[S] Switching mode FragmentFree
[U] Use of store-and-forward for multicast Disabled
[A] Action upon address violation Suspend
[G] Generate alert on address violation Enabled
[I] Address aging time 300 second(s)
[P] Network port None
[H] Half duplex back pressure (10-mbps ports) Disabled
[E] Enhanced congestion control (10-mbps ports) Disabled
----------------------- Actions ----------------------------------------
[R] Reset system [F] Reset to factory defaults
----------------------- Related Menus ----------------------------------
[B] Broadcast storm control [X] Exit to Main Menu
Enter Selection: F
This command resets the switch. All configured system parameters and
static addresses will be retained. All dynamic addresses will be removed.
Reset system, [Y]es or [N]o? Yes
|
User Interface Menu
[M] Menus
[I] IP Configuration
[P] Console Password
Enter Selection: I
|
Catalyst 1900 - IP Configuration
Ethernet Address: 00-90-B1-66-0F-80
----------------------- Settings ---------------------------------------
[I] IP address 0.0.0.0
[S] Subnet mask 0.0.0.0
[G] Default gateway 0.0.0.0
[B] Management bridge group 1 (always)
[M] IP address of DNS server 1 0.0.0.0
[N] IP address of DNS server 2 0.0.0.0
[D] Domain name
[R] Use Routing Information Protocol Enabled
----------------------- Actions ----------------------------------------
[P] Ping
[C] Clear cached DNS entries
[X] Exit to previous menu
Enter Selection: I
This command assigns an administrative IP address to this switch.
The new address will take effect immediately.
If no IP address is assigned (or if the IP address is removed by setting
it to 0.0.0.0), and the switch is connected to a DHCP server, the DHCP
server may automatically assign an address to the switch.
Enter administrative IP address in dotted quad format (nnn.nnn.nnn.nnn):
Current setting ===> 0. 0. 0. 0
New setting ===> 169.254.1.250
|
Catalyst 1900 - IP Configuration
Ethernet Address: 00-90-B1-66-0F-80
----------------------- Settings ---------------------------------------
[I] IP address 169.254.1.250
[S] Subnet mask 0.0.0.0
[G] Default gateway 0.0.0.0
[B] Management bridge group 1 (always)
[M] IP address of DNS server 1 0.0.0.0
[N] IP address of DNS server 2 0.0.0.0
[D] Domain name
[R] Use Routing Information Protocol Enabled
----------------------- Actions ----------------------------------------
[P] Ping
[C] Clear cached DNS entries
[X] Exit to previous menu
Enter Selection: S
This command defines the subnet mask for the IP address set by the
[I] IP Address command.
Enter IP subnet mask in dotted quad format (nnn.nnn.nnn.nnn):
Current setting ===> 0. 0. 0. 0
New setting ===> 255.255.255.0
|
Catalyst 1900 - IP Configuration
Ethernet Address: 00-90-B1-66-0F-80
----------------------- Settings ---------------------------------------
[I] IP address 169.254.1.250
[S] Subnet mask 255.255.255.0
[G] Default gateway 0.0.0.0
[B] Management bridge group 1 (always)
[M] IP address of DNS server 1 0.0.0.0
[N] IP address of DNS server 2 0.0.0.0
[D] Domain name
[R] Use Routing Information Protocol Enabled
----------------------- Actions ----------------------------------------
[P] Ping
[C] Clear cached DNS entries
[X] Exit to previous menu
Enter Selection: P
This command verifies if an IP device can be reached from this switch.
The IP device can be specified either as an IP address or device name.
If a name is given then it will be resolved to an IP address using DNS
service.
Enter IP address or name ===> 169.254.1.1
Press Q to terminate ping session.
Sending 5, 100-byte ICMP Echos to 169.254.1.1, time out is 2 seconds:
!!!!!
Success rate is 100 percent (5/5), round-trip min/avg/max 0/2/10/ ms
Press any key to continue.
|
Catalyst 1900 - IP Configuration
Ethernet Address: 00-90-B1-66-0F-80
----------------------- Settings ---------------------------------------
[I] IP address 169.254.1.1
[S] Subnet mask 255.255.255.0
[G] Default gateway 0.0.0.0
[B] Management bridge group 1 (always)
[M] IP address of DNS server 1 0.0.0.0
[N] IP address of DNS server 2 0.0.0.0
[D] Domain name
[R] Use Routing Information Protocol Enabled
----------------------- Actions ----------------------------------------
[P] Ping
[C] Clear cached DNS entries
[X] Exit to previous menu
Enter Selection: X
|
User Interface Menu
[M] Menus
[I] IP Configuration
[P] Console Password
Enter Selection: M
|
Catalyst 1900 - Main Menu
[C] Console Settings
[S] System
[N] Network Management
[P] Port Configuration
[A] Port Addressing
[D] Port Statistics Detail
[M] Monitoring
[B] Bridge Group
[R] Multicast Registration
[F] Firmware
[I] RS-232 Interface
[U] Usage Summaries
[H] Help
[X] Exit Management Console
Enter Selection: F
|
Catalyst 1900 - Firmware Configuration
----------------------- System Information -----------------------------
FLASH: 1024K bytes
V9.00.05 : Standard Edition
Upgrade status:
No upgrade currently in progress.
----------------------- Settings ---------------------------------------
[S] TFTP Server name or IP address
[F] Filename for firmware upgrades
[A] Accept upgrade transfer from other hosts Disabled
----------------------- Actions ----------------------------------------
[U] System XMODEM upgrade [D] Download test subsystem (XMODEM)
[T] System TFTP upgrade [X] Exit to Main Menu
Enter Selection: S
Specify the name or IP address of a TFTP server where an upgrade file is located
.
Use the [F] Filename for firmware upgrades command to define the name of
the upgrade file residing on that server. Then issue the appropriate TFTP
upgrade command to carry out the firmware upgrade process.
Enter TFTP server name IP address in dotted quad format (nnn.nnn.nnn.nnn):
Current setting ===>
New setting ===> 169.254.1.1
|
Catalyst 1900 - Firmware Configuration
----------------------- System Information -----------------------------
FLASH: 1024K bytes
V9.00.05 : Standard Edition
Upgrade status:
No upgrade currently in progress.
----------------------- Settings ---------------------------------------
[S] TFTP Server name or IP address 169.254.1.1
[F] Filename for firmware upgrades
[A] Accept upgrade transfer from other hosts Disabled
----------------------- Actions ----------------------------------------
[U] System XMODEM upgrade [D] Download test subsystem (XMODEM)
[T] System TFTP upgrade [X] Exit to Main Menu
Enter Selection: F
Specify the name of a firmware upgrade file residing on a TFTP server.
Use the [S] Server: IP address of TFTP server command to specify
the address of that server. Then issue the appropriate TFTP upgrade
command to carry out the firmware upgrade process.
Enter upgrade filename (80 characters max):
Current setting ===>
New setting ===> cat1900EN.9.00.05.bin
|
Catalyst 1900 - Firmware Configuration
----------------------- System Information -----------------------------
FLASH: 1024K bytes
V9.00.05 : Standard Edition
Upgrade status:
No upgrade currently in progress.
----------------------- Settings ---------------------------------------
[S] TFTP Server name or IP address 169.254.1.1
[F] Filename for firmware upgrades cat1900EN.9.00.05.bi
[A] Accept upgrade transfer from other hosts Disabled
----------------------- Actions ----------------------------------------
[U] System XMODEM upgrade [D] Download test subsystem (XMODEM)
[T] System TFTP upgrade [X] Exit to Main Menu
Enter Selection: A
The switch contains a TFTP listener which can accept a firmware upgrade
transfer from other hosts on the network. To prevent possible
unauthorized upgrades from network users, specify Disabled when prompted.
TFTP listener may be [E]nabled to accept, or [D]isabled from accepting
upgrade transfer from other hosts:
Current setting ===> Disabled
New setting ===> Enabled
|
Catalyst 1900 - Firmware Configuration
----------------------- System Information -----------------------------
FLASH: 1024K bytes
V9.00.05 : Standard Edition
Upgrade status:
No upgrade currently in progress.
----------------------- Settings ---------------------------------------
[S] TFTP Server name or IP address 169.254.1.1
[F] Filename for firmware upgrades cat1900EN.9.00.05.bi
[A] Accept upgrade transfer from other hosts Enabled
----------------------- Actions ----------------------------------------
[U] System XMODEM upgrade [D] Download test subsystem (XMODEM)
[T] System TFTP upgrade [X] Exit to Main Menu
Enter Selection: T
This upgrade will overwrite the firmware version V9.00 in FLASH memory.
AT THE END OF THE UPGRADE, THE SWITCH MAY NOT RESPOND
TO COMMANDS FOR AS LONG AS ONE MINUTE.
THIS IS NORMAL BEHAVIOR AND DO NOT TURN SWITCH OFF DURING THAT TIME.
The TFTP protocol will be used to perform this firmware upgrade.
This command requires the IP address of a TFTP server and the name
of an upgrade file residing on that server. Use the following commands
[S] Server: IP address of TFTP server, and
[F] Filename for firmware upgrades
to complete these requirements before starting the upgrade.
Do you wish to continue with the upgrade process, [Y]es or [N]o? Yes
TFTP transfer of cat1900EN.9.00.05.bin from server at 169.254.1.1 initiated...
Press any key to continue.
|
User Interface Menu
[M] Menus
[K] Command Line
[I] IP Configuration
[P] Console Password
Enter Selection:
|